RDE
Most closed-loop motors controllers require the incremental quadrature feedback that
encoders provide. Empire Magnetics' RDE resolver-to-digital converter module closes the
loop betwen rugged feedback resolvers and motor controllers that require encoder feedback.
RDE converters connect easily to Empire Magnetics resolvers, providing complementary
TTL compatible two phase quadrature and outputs with index (Channels A, B, and Z).
For a more detailed look
at the specifications, consult the RDE
Manual.
Features
- Ratiometric conversion technique--provides good electrical noise immunity,
accomodates long cables
- 1,024 cycles per revolution--yields 4,906 encoder counts
- Built-in power supply
- Optically isolated encoder interface
- Open collector or line driver outputs
|
RDE Specifications
| Model Number |
RDE |
RDE-B |
RDE-L |
| Option |
Standard |
Binary position
data outputs |
RS-422 line
driver outputs |
| Drawing Number |
C/F |
C/F |
C/F |
| Voltage |
105-125 VAC,
50-60 Hz |
105-125 VAC,
50-60 Hz |
105-125 VAC,
50-60 Hz |
| Current (A) |
0.25 |
0.25 |
0.25 |
| Encoder Interface |
+5 VDC
@ 50 mA max. |
+5 VDC
@ 50 mA max. |
+5 VDC
@ 50 mA max. |
Open Collector
Current (mA) |
-25 |
-25 |
-25 |
Resolution (cycles
per revolution) |
1024 |
1024 |
1024 |
| Accuracy (+/- degrees) |
0.3 |
0.3 |
0.3 |
Operating Temperature
Range (degrees C) |
0 to 60 |
0 to 60 |
0 to 60 |
Storage Temperature
Range (degrees C) |
-55 to 150 |
-55 to 150 |
-55 to 150 |
Encoder Connector
(DB25S pinout)
|
1.
2.
3.
4.
5.
6.
8.
14.-19.
24. |
Channel A+
Channel A-
Channel B+
Channel B-
Channel Z+
Channel Z-
Shield
GND
+5VDC |
RDE